ConstructSim Planner CONNECT Edition Update 5 Help

Extensions Configuration Variables

The following table lists the configuration variables that affect extensions. Each configuration variable expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration variable change to take effect.

Variable Description
MS_GROUPPANELPREF Defines the location of the file that stores the saved state of group panels in various dialogs. These include dialogs such as View Attributes, and stores the open state of the groups, as well as any custom settings that the dialog can associate with the groups.
MS_TASKDIALOGPREF Defines the location of the file used to store preferences about the Tasks dialog between sessions. This file stores info such as the last active task, the last active task dialog, and the task layout mode. Do not modify this file.
MS_DOCKINGPREF Defines the location of the file that stores docking preferences such as which dialogs are docked, where they are docked, and the size of the docking areas.
MS_SKETCHUP_IMAGE Stores the texture images that are embedded in the SketchUp files when the SketchUp file is saved as a DGN file.
KS_STRUCOBJ_DISPLAYMODE Determines if structural objects are displayed in rendering mode. If set to 0, do not display in rendering mode; if set to 1, display in rendering mode. The default is 1.
KS_WORKFRAME_DISPLAYMODE Determines if workframes are displayed in rendering mode. If set to 0, do not display in rendering mode; if set to 1, display in rendering mode. The default is 1.
KS_BOLT_DISPLAYMODE Determines if bolts display. If set to 0, bolts do not display; if set to 1, they display. The default is 1.
KS_HOLE_DISPLAYMODE Determines if holes display in true extrusion. If set to 0, they do not display; if set to 1, they display. The default is 1.
MS_POINTCLOUD_APPS Loads any specified MDL applications along with the PointCloud Handler whenever a point cloud is attached in a model. To load the MDL application every time you attach a point cloud, add the name of the MDL application to this variable.
MS_SELECTSERVICESHOME URL of Bentley SELECTservices homepage.
MS_REALDWG_APPS Lists the adapters for cooperative object enablers that load when the product starts.
MS_GPSDEVICES Specifies the supported GPS devices. Do not modify this configuration variable.
MS_GEOCOORDINATE_REPROJECTIONSETTINGS Directory where the reprojection settings are stored. Do not modify this configuration variable.
MS_GEOCOORDINATE_REFSETTINGS Directory where the default reference reprojection settings are stored. Do not modify this configuration variable.
MS_GEOCOORDINATE_FAVORITESFILES Directory set aside for quick access to geographic coordinate systems. The contents of this directory appear in the Favorites folder on the Select Geographic Coordinate System dialog’s Library tab.
MS_GEOCOORDINATE_DATA Directory where GeoCoordinate data is installed.
MS_ELEMENTEXPLORER_ENABLERS This variable defines the Element Explorer Enabler applications.
MS_PROCESSEXCEPTIONLOG Use to manage exception.log and minidump.dmp.
MS_CUSTOMIZE_REPORT_STYLESHEET Defines the file name and location for HTML reports on templates and customizations. The default style sheet is named “customizereport.xsl” and is stored in ..\WorkSpace\System\Data.
MS_BATCHPLT_SPECS Sets the location of the batchplt.spc file, which contains the print specifications.
MS_FONTCONFIGFILE Specifies the full path of the font configuration file. Default path is “$(MS_SYSFONTDIR)/MstnFontConfig.xml”.
MS_SELECTBY Defines the directory where the selectby.rsc file is written to or read from. The selectby.rsc is used by the Select by Attributes tool to save and retrieve sets of selection criteria. The default setting is MS_SELECTBY=$(_USTN_HOMEROOT).
MS_BUTTONMENU Defines the file name that holds the mouse button menu. The default name is “default.btnmenu” located in the MS_DATA directory.
MS_DATA_PDFL Used for internal implementation only. Do not modify this configuration variable.
MS_SHAREDCONENTDIR Directory containing shared content files.
MS_RASTER_DEF_DIR If absent, there is no Effect. If present, defines the default directory to which the Attach Raster Reference menu will point to (Default raster file open directory).
MS_POINTOOLS Points to the directory where the DLLs related to Pointools are stored.
MS_LUXOLOGY Points to the directory where the DLLs related to Luxology are stored.
MS_ACIS Directory containing the ACIS subsystem.
MS_SYSFONTDIR Directory containing the system fonts.
MS_SYMBOLPROVIDER_APPS Allows developers to register a managed assembly as an application that provides additional symbols for use in named expressions.
MS_TASKMAPFILES Used for internal implementation only. Do not modify this configuration variable.
MS_INPUT_CONFIGXML Directory containing the inputconfiguration.xml file, which is used to store gesture assignments.
MS_ICONRSCLIST Directories containing .rsc files for icons.
MS_ICONLIBRARYLIST Directories containing .dll files for icons.
MS_ICONPATH Directories containing files for icons.
MS_ECREPOSITORY_PROPERTYENABLER_SKIPPED_ECSCHEMAS Used to remove certain item types from appearing in the Items dialog and Search dialog. The list is delimited by semicolons and the ECSchema names must be fully qualified with their version number, for example, “MySchema.01.00;BentleyPlant.05.00”. Do not modify this configuration variable.
MS_CLRUICULTURE Used for internal implementation. Do not modify this configuration variable.
MS_XATTRIBUTE_HANDLER_LOAD Used to control terrain model elements. This variable should not be changed by users.
MS_HANDLER_LOAD Used to control element handlers. Do not modify this configuration variable.
MS_PROPERTYENABLER_APPS Lists the applications to be loaded that are required for displaying properties in the Element Information dialog.
MS_TEMPLATEEXTENDER_APPS Used to make terrain model properties available in the Element Templates dialog.
MS_PRODUCTCODEGUID Used for internal implementation. Do not modify this configuration variable.
MSDIR_INSTALLED Directory where the product is installed.
EC_EXTENSION_ASSEMBLIES Used for internal implementation. Do not modify this configuration variable.